Core Tip: The vibrating table is suitable for the relevant vibration test of samples in the laboratory and production line of auto parts, electronic components, components, medicine, food, furniture, gifts, ceramics, packaging and so on. Such as environmental acceptance test, quality identification test, reliability identification test, endurance test, vibration simulation analysis, material property test, fatigue test, vibration prevention improvement, etc.
The main technical parameters:
Speed: 50~330rpm adjustable
Amplitude (displacement): 25.4mmP-P
Maximum load: 1T
Programmable digital timer: 0.1 seconds to 99.59 hours
Work surface size: (L × W × H) 2090 × 1600 × 1615mm
Fence height: 1000mm
Movement mode: reciprocating (rotary)
Power consumption: 5.33HP
Power supply: 380V/220V50Hz
Weight: 1200kg
Precautions for the simulated transport vibration tester:
First, equipment inspection
1. Check the position of the vibration isolation mechanism; let the magnetic steel of the vibration table be in a reasonable position;
2. Check if the signal excitation output line of the controller is reliably connected;
3. If the level test is carried out, turn the table body to the horizontal state and check accordingly according to the relevant contents of the equipment manual.
Second, the simulation of the transport vibration table on the installation of the test piece
1. Turn on the air pump and manually adjust the air pressure of the center airbag to the center position;
2. Fixtures and test pieces are installed in strict accordance with the requirements of the test task book;
3. The installation of the sensory room sensor is strictly adhered to the requirements of the test task book and used as the designated purpose;
4. Connect the sensor to the controller channel specified in the test task book with the corresponding signal line;
Third, the simulation transport shaker boot sequence
1. Turn on the system power supply, make sure the gain switch is in the reset position, and close the power amplifier leakage circuit breaker;
2. Set the test parameters correctly according to the requirements of the test task and save them. If the test data is called, it must be checked whether the test settings are consistent with the test task book;
3. Press the power button and the fan will start. Open the gain knob to the appropriate position (refer to the instruction manual) / At this time, the “Prepareâ€, “Start†and “Power†lights are on, and the system enters the standby state.
4. Run the test, record the state of the test piece and the state of the test equipment in real time, and save the corresponding test data.
Concerned about surprises
Label: Shaking table technical parameters and precautions
Previous: Brief description of the working principle of quick unloading valve Next: Common solenoid valve sealing material
SHENZHEN YGHQ Optoelectronics Co.,ltd. , https://www.leds-smd.com