Model NO.: BA-NT838A
Kind: Manual Focus Lens
Certification: CE, FCC, RoHS, ISO9001: 2000
Feature: Waterproof / Weatherproof, High Definition, Vandal-proof, Auto BLC
Effective Distance: ≧30m
Sensor Size: 1/3 inch
Remote Control: With Remote Control
Trademark: Banovision or OEM
Transport Package: Carton
Origin: Shenzhen
HS Code: 8525801390
Model NO.: BA-NT838A
Kind: Manual Focus Lens
Certification: CE, FCC, RoHS, ISO9001: 2000
Feature: Waterproof / Weatherproof, High Definition, Vandal-proof, Auto BLC
Effective Distance: ≧30m
Sensor Size: 1/3 inch
Remote Control: With Remote Control
Trademark: Banovision or OEM
Transport Package: Carton
Origin: Shenzhen
HS Code: 8525801390
Features:• 384 x 288 uncooled FPA detector
• 50HZ Real time imaging
• Front end temperature measurement, high accurate
• H.264 network video record and transmission
• IP54(Support IP67 customization)
• Temp measurement range -20ºC~+650ºC(Can be expanded to 1200ºC )
• Offer SDK free
Application:
Suitable for industrial process control, Electronic non-touch temperature measurement, electric fault detection and thermal field analysis
Specification:
Model | BA-NT838A | ||
Detector characteristics | |||
Detector | Uncooled FPA microbolometer | ||
resolution | 384×288 | ||
Pitch size | 25μm | ||
Spectral range | 8~14μm | ||
Thermal Image | |||
Focal length | 9mm | 18mm | 37mm |
IFOV | 2.78mrad | 1.39mrad | 0.67mrad |
FOV/Min Focus | 51°×38°/0.1m | 25°×19°/0.1m | 12°×9°/0.5 |
Thermal sensitivity | ≤0.06ºC@30ºC | ||
Frame Frequency | 50/60HZ | ||
Focus | Auto/electronic focus/Preset | ||
Measurement Function | |||
Measurement range | 20 ºC~+650 ºC | ||
measurement correction | Auto/Manual | ||
Measurement accuracy | ±2ºC or ±2% of reading, whichever is greater | ||
Measurement mode | Up to 4 movable spots. Up to 3 movable areas | ||
Color Palette | 11 palettes available(including iron red, rainbow, black/white etc) | ||
image adjustment | Auto/manual Gain, brightness | ||
Setup function | Temperature unit,language,IP address | ||
Emissivity correction | Variable from 0.01 to 1.0Â | ||
ambient temperature correction | Automatic correction according to user input | ||
Atmospheric transmission correction | automatic correction according to the user input of object distance, relative humidity, ambient temperature | ||
Image storage | |||
Raw image capture | Raw images real-time transfer via client control software, the images are analyzable and measureable | ||
Image storage | H.264 continuous video. Single image capture BMP | ||
Power Supply | |||
Power in | 10~15V DC | ||
Power consumption | ≤7W(@ 25ºC normal operation) | ||
Environment | |||
Operating temperature | -15ºC~ +50ºC | ||
Storage temperature | -40ºC~+70ºC | ||
Encapsulation | IP54 | ||
Physical characteristics | |||
Weight | ≤1Kg(Standard lens) | ||
Size | W72mm×H76×D232mm(Standard lens) | ||
Interface | |||
Power port | YES | ||
Analog video output | PAL | ||
Digital video output | RJ-45 Ethernet output(1000Mbit/S) | ||
Serial Port | RS485(optional) |
 Features:
• 384 x 288 uncooled FPA detector
• 50HZ Real time imaging
• Front end temperature measurement, high accurate
• H.264 network video record and transmission
• IP54(Support IP67 customization)
• Temp measurement range -20ºC~+650ºC(Can be expanded to 1200ºC )
• Offer SDK free
Application:
Suitable for industrial process control, Electronic non-touch temperature measurement, electric fault detection and thermal field analysis
Specification:
Model | BA-NT838A | ||
Detector characteristics | |||
Detector | Uncooled FPA microbolometer | ||
resolution | 384×288 | ||
Pitch size | 25μm | ||
Spectral range | 8~14μm | ||
Thermal Image | |||
Focal length | 9mm | 18mm | 37mm |
IFOV | 2.78mrad | 1.39mrad | 0.67mrad |
FOV/Min Focus | 51°×38°/0.1m | 25°×19°/0.1m | 12°×9°/0.5 |
Thermal sensitivity | ≤0.06ºC@30ºC | ||
Frame Frequency | 50/60HZ | ||
Focus | Auto/electronic focus/Preset | ||
Measurement Function | |||
Measurement range | 20 ºC~+650 ºC | ||
measurement correction | Auto/Manual | ||
Measurement accuracy | ±2ºC or ±2% of reading, whichever is greater | ||
Measurement mode | Up to 4 movable spots. Up to 3 movable areas | ||
Color Palette | 11 palettes available(including iron red, rainbow, black/white etc) | ||
image adjustment | Auto/manual Gain, brightness | ||
Setup function | Temperature unit,language,IP address | ||
Emissivity correction | Variable from 0.01 to 1.0Â | ||
ambient temperature correction | Automatic correction according to user input | ||
Atmospheric transmission correction | automatic correction according to the user input of object distance, relative humidity, ambient temperature | ||
Image storage | |||
Raw image capture | Raw images real-time transfer via client control software, the images are analyzable and measureable | ||
Image storage | H.264 continuous video. Single image capture BMP | ||
Power Supply | |||
Power in | 10~15V DC | ||
Power consumption | ≤7W(@ 25ºC normal operation) | ||
Environment | |||
Operating temperature | -15ºC~ +50ºC | ||
Storage temperature | -40ºC~+70ºC | ||
Encapsulation | IP54 | ||
Physical characteristics | |||
Weight | ≤1Kg(Standard lens) | ||
Size | W72mm×H76×D232mm(Standard lens) | ||
Interface | |||
Power port | YES | ||
Analog video output | PAL | ||
Digital video output | RJ-45 Ethernet output(1000Mbit/S) | ||
Serial Port | RS485(optional) |